absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
†
LM2902-Q1 LM2902KV-Q1 UNIT
Supply voltage, V
CC
(see Note 1) 26 32 V
Differential input voltage, V
ID
(see Note 2) ±26 ±32 V
Input voltage, V
I
(either input) −0.3 to 26 −0.3 to 32 V
Duration of output short circuit (one amplifier) to ground at (or below) T
A
= 25°C, V
CC
≤ 15 V (see
Note 3)
Unlimited Unlimited
Package thermal impedance θ (see Notes 4 and 5)
D package (0 LFPM) 101 101
°C/W
Package thermal impedance, θ
JA
(see Notes 4 and 5)
PW package 113 113
°C/W
Operating virtual junction temperature, T
J
142 142 °C
Storage temperature range, T
stg
−65 to 150 −65 to 150 °C
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values, except differential voltages and V
CC
specified for the measurement of I
OS
, are with respect to the network GND.
2. Differential voltages are at IN+ with respect to IN−.
3. Short circuits from outputs to V
CC
can cause excessive heating and eventual destruction.
4. Maximum power dissipation is a function of T
J
(max), θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable
ambient temperature is P
D
= (T
J
(max) − T
A
)/θ
JA
. Operating at the absolute maximum T
J
of 142°C can affect reliability.
5. The package thermal impedance is calculated in accordance with JESD 51-7.