Datasheet
LM2825
www.ti.com
SNVS127C –MAY 1997–REVISED APRIL 2013
OUTPUT CURRENT DERATING FOR T
A
= 70°C to 85°C
At high these high ambient temperatures, the LM2825 cannot supply the full one ampere over the entire input
and output voltage range. This is due to thermal reasons and Figure 23 shows the typical available output
current for any input and output voltage combination. This applies for all output voltage versions.
Figure 23. LM2825 Output Current Derating for T
A
= 70°C to 85°C
Figure 24. Typical Circuits Using Shutdown/Soft-start Features
Copyright © 1997–2013, Texas Instruments Incorporated Submit Documentation Feedback 15
Product Folder Links: LM2825