Datasheet

LM2679
www.ti.com
SNVS026N MARCH 2000REVISED APRIL 2013
Operating Ratings
Supply Voltage 8V to 40V
Junction Temperature Range (T
J
) 40°C to 125°C
Electrical Characteristics
LM2679-3.3
Limits appearing in bold type face apply over the entire junction temperature range of operation, 40°C to 125°C.
Specifications appearing in normal type apply for T
A
= T
J
= 25°C. R
ADJ
= 5.6K.
Symbol Parameter Conditions Min
(1)
Typ
(2)
Max
(1)
Units
V
OUT
Output Voltage V
IN
= 8V to 40V, 100mA I
OUT
5A 3.234/3.201 3.3 3.366/3.399 V
η Efficiency V
IN
= 12V, I
LOAD
= 5A 82 %
(1) All limits are specified at room temperature (standard type face) and at temperature extremes (bold type face). All room temperature
limits are 100% tested during production with T
A
= T
J
= 25°C. All limits at temperature extremes are specified via correlation using
standard Quality Control (SQC) methods. All limits are used to calculate Average Outgoing Quality Level (AOQL).
(2) Typical values are determined with T
A
= T
J
= 25°C and represent the most likely norm.
LM2679-5.0
Symbol Parameter Conditions Min
(1)
Typ
(2)
Max
(1)
Units
V
OUT
Output Voltage V
IN
= 8V to 40V, 100mA I
OUT
5A 4.900/4.850 5.0 5.100/5.150 V
η Efficiency V
IN
= 12V, I
LOAD
= 5A 84 %
(1) All limits are specified at room temperature (standard type face) and at temperature extremes (bold type face). All room temperature
limits are 100% tested during production with T
A
= T
J
= 25°C. All limits at temperature extremes are specified via correlation using
standard Quality Control (SQC) methods. All limits are used to calculate Average Outgoing Quality Level (AOQL).
(2) Typical values are determined with T
A
= T
J
= 25°C and represent the most likely norm.
LM2679-12
Symbol Parameter Conditions Min
(1)
Typ
(2)
Max
(1)
Units
V
OUT
Output Voltage V
IN
= 15V to 40V, 100mA I
OUT
5A 11.76/11.64 12 12.24/12.36 V
η Efficiency V
IN
= 24V, I
LOAD
= 5A 92 %
(1) All limits are specified at room temperature (standard type face) and at temperature extremes (bold type face). All room temperature
limits are 100% tested during production with T
A
= T
J
= 25°C. All limits at temperature extremes are specified via correlation using
standard Quality Control (SQC) methods. All limits are used to calculate Average Outgoing Quality Level (AOQL).
(2) Typical values are determined with T
A
= T
J
= 25°C and represent the most likely norm.
LM2679-ADJ
Symbol Parameter Conditions Min
(1)
Typ
(2)
Max
(1)
Units
V
FB
Feedback V
IN
= 8V to 40V, 100mA I
OUT
5A
1.186/1.174 1.21 1.234/1.246 V
Voltage V
OUT
Programmed for 5V
η Efficiency V
IN
= 12V, I
LOAD
= 5A 84 %
(1) All limits are specified at room temperature (standard type face) and at temperature extremes (bold type face). All room temperature
limits are 100% tested during production with T
A
= T
J
= 25°C. All limits at temperature extremes are specified via correlation using
standard Quality Control (SQC) methods. All limits are used to calculate Average Outgoing Quality Level (AOQL).
(2) Typical values are determined with T
A
= T
J
= 25°C and represent the most likely norm.
Copyright © 2000–2013, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Links: LM2679