Datasheet

LM26003
www.ti.com
SNVS576D AUGUST 2008REVISED MARCH 2013
Absolute Maximum Ratings
(1)(2)
Voltages from the indicated pins to GND:
VIN -0.3V to 40V
SW
(3)
-1V to 40V
VDD -0.3V to 7V
VBIAS -0.3V to 10V
FB -0.3V to 6V
BOOT V
SW
-0.3V to V
SW
+7V
PGOOD -0.3V to 7V
FREQ -0.3V to 7V
SYNC -0.3V to 7V
EN -0.3V to 40V
FPWM -0.3V to 7V
Storage Temperature -65°C to +150°C
Power Dissipation
(4)
3.1W
Recommended Lead Temperature Vapor Phase (70s) 215°C
Infrared (15s) 220°C
ESD Susceptibility
(5)
Human Body Model 2 kV
(1) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur, including inoperability and degradation of
device reliability and/or performance. Functional operation of the device and/or non-degradation at the Absolute Maximum Ratings or
other conditions beyond those indicated in the recommended Operating Ratings is not implied. The recommended Operating Ratings
indicate conditions at which the device is functional and should not be operated beyond such conditions.
(2) If Military/Aerospace specified devices are required, please contact the Texas Instruments Sales Office/Distributors for availability and
specifications.
(3) The absolute maximum specification applies to DC voltage. An extended negative voltage limit of -3V applies for a pulse of up to 200
ns, and -6V for a pulse of up to 50 ns.
(4) The maximum allowable power dissipation is a function of the maximum junction temperature, T
J_MAX
, the junction-to-ambient thermal
resistance, θ
JA
, and the ambient temperature, T
A
. The maximum allowable power dissipation at any ambient temperature is calculated
using: P
D_MAX
= (T
J_MAX
- T
A
) /θ
JA
. The maximum power dissipation of 3.1W is determined using T
A
= 25°C, θ
JA
= 32°C/W, and T
J_MAX
= 125°C.
(5) The human body model is a 100 pF capacitor discharged through a 1.5 k resistor into each pin.
Operating Ratings
(1)
Operating Junction Temperature 40°C to 125°C
Supply Voltage
(2)
3.0V to 38V
(1) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur, including inoperability and degradation of
device reliability and/or performance. Functional operation of the device and/or non-degradation at the Absolute Maximum Ratings or
other conditions beyond those indicated in the recommended Operating Ratings is not implied. The recommended Operating Ratings
indicate conditions at which the device is functional and should not be operated beyond such conditions.
(2) Below 4.0V input, power dissipation may increase due to increased R
DS(ON)
. Therefore, a minimum input voltage of 4.0V is required to
operate continuously within specification. A minimum of 3.9V (typical) is also required for startup.
Copyright © 2008–2013, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Links: LM26003