Datasheet
LM2597, LM2597HV
www.ti.com
SNVS119C –MARCH 1998–REVISED APRIL 2013
LM2597/LM2597HV-12
Electrical Characteristics
Specifications with standard type face are for T
J
= 25°C, and those with boldface type apply over full Operating
Temperature Range.V
INmax
=40V for the LM2597 and 60V for the LM2597HV
Symbol Parameter Conditions LM2597/LM2597HV-12 Units
(Limits)
Typ
(1)
Limit
(2)
SYSTEM PARAMETERS Test Circuit Figure 31
(3)(4)
V
OUT
Output Voltage 15V ≤ V
IN
≤ V
INmax
, 0.1A ≤ I
LOAD
≤ 0.5A 12 V
11.52/11.40 V(min)
12.48/12.60 V(max)
η Efficiency V
IN
= 25V, I
LOAD
= 0.5A 88 %
(1) Typical numbers are at 25°C and represent the most likely norm.
(2) All limits specified at room temperature (standard type face) and at temperature extremes (bold type face). All room temperature limits
are 100% production tested. All limits at temperature extremes are specified via correlation using standard Statistical Quality Control
(SQC) methods. All limits are used to calculate Average Outgoing Quality Level (AOQL).
(3) External components such as the catch diode, inductor, input and output capacitors can affect switching regulator system performance.
When the LM2597/LM2597HV is used as shown in the Figure 31 test circuit, system performance will be as shown in system
parameters section of Electrical Characteristics.
(4) No diode, inductor or capacitor connected to output pin.
LM2597/LM2597HV-ADJ
Electrical Characteristics
Specifications with standard type face are for T
J
= 25°C, and those with boldface type apply over full Operating
Temperature Range.V
INmax
=40V for the LM2597 and 60V for the LM2597HV
Symbol Parameter Conditions LM2597/LM2597HV-ADJ Units
(Limits)
Typ
(1)
Limit
(2)
SYSTEM PARAMETERS Test Circuit Figure 31
(3)(4)
V
FB
Feedback Voltage 4.5V ≤ V
IN
≤ V
INmax
, 0.1A ≤ I
LOAD
≤ 0.5A 1.230 V
V
OUT
programmed for 3V. Circuit of Figure 31. 1.193/1.180 V(min)
1.267/1.280 V(max)
η Efficiency V
IN
= 12V, V
OUT
= 3V, I
LOAD
= 0.5A 80 %
(1) Typical numbers are at 25°C and represent the most likely norm.
(2) All limits specified at room temperature (standard type face) and at temperature extremes (bold type face). All room temperature limits
are 100% production tested. All limits at temperature extremes are specified via correlation using standard Statistical Quality Control
(SQC) methods. All limits are used to calculate Average Outgoing Quality Level (AOQL).
(3) External components such as the catch diode, inductor, input and output capacitors can affect switching regulator system performance.
When the LM2597/LM2597HV is used as shown in the Figure 31 test circuit, system performance will be as shown in system
parameters section of Electrical Characteristics.
(4) No diode, inductor or capacitor connected to output pin.
Copyright © 1998–2013, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Links: LM2597 LM2597HV