Datasheet
LM158, LM158A, LM258, LM258A
LM358, LM358A, LM2904, LM2904V
SLOS068S –JUNE 1976–REVISED MAY 2013
www.ti.com
Electrical Characteristics
at specified free-air temperature, V
CC
= 5 V (unless otherwise noted)
LM158 LM258 LM358
PARAMETER TEST CONDITIONS
(1)
T
A
(2)
UNIT
MIN TYP
(3)
MAX MIN TYP
(3)
MAX
25°C 3 5 3 7
V
CC
= 5 V to MAX, V
IC
= V
ICR
min,
V
IO
Input offset voltage mV
V
O
= 1.4 V
Full range 7 9
Average temperature coefficient of
αV
IO
Full range 7 7 µV/°C
input offset voltage
25°C 2 30 2 50
I
IO
Input offset current V
O
= 1.4 V nA
Full range 100 150
Average temperature coefficient of
αI
IO
Full range 10 10 pA/°C
input offset current
25°C –20 –150 –20 –250
I
IB
Input bias current V
O
= 1.4 V nA
Full range –300 –500
0 to 0 to
25°C
V
CC
– 1.5 V
CC
– 1.5
V
ICR
Common-mode input voltage range V
CC
= 5 V to MAX V
0 to 0 to
Full range
V
CC
– 2 V
CC
– 2
R
L
≥ 2 kΩ 25°C V
CC
– 1.5 V
CC
– 1.5
R
L
≥ 10 kΩ 25°C
V
OH
High-level output voltage V
R
L
= 2 kΩ Full range 26 26
V
CC
= MAX
R
L
≥ 10 kΩ Full range 27 28 27 28
V
OL
Low-level output voltage R
L
≤ 10 kΩ Full range 5 20 5 20 mV
V
CC
= 15 V 25°C 50 100 25 100
Large-signal differential voltage
V
O
= 1 V to 11 V,
A
VD
V/mV
amplification
Full range 25 15
R
L
≥ 2 kΩ
V
CC
= 5 V to MAX,
CMRR Common-mode rejection ratio 25°C 70 80 65 80 dB
V
IC
= V
ICR(min)
Supply-voltage rejection ratio
k
SVR
V
CC
= 5 V to MAX 25°C 65 100 65 100 dB
(ΔV
DD
/ΔV
IO
)
V
O1
/ V
O2
Crosstalk attenuation f = 1 kHz to 20 kHz 25°C 120 120 dB
V
CC
= 15 V, 25°C –20 –30 –20 –30
V
ID
= 1 V, Source
Full range –10 –10
V
O
= 0
mA
I
O
Output current V
CC
= 15 V, 25°C 10 20 10 20
V
ID
= –1 V, Sink
Full range 5 5
V
O
= 15 V
V
ID
= –1 V, V
O
= 200 mV 25°C 12 30 12 30 μA
V
CC
at 5 V, V
O
= 0,
I
OS
Short-circuit output current 25°C ±40 ±60 ±40 ±60 mA
GND at –5 V
V
O
= 2.5 V, No load Full range 0.7 1.2 0.7 1.2
I
CC
Supply current (two amplifiers) mA
V
CC
= MAX, V
O
= 0.5 V
CC
,
Full range 1 2 1 2
No load
(1) All characteristics are measured under open-loop conditions, with zero common-mode input voltage, unless otherwise specified. MAX
V
CC
for testing purposes is 26 V for LM2902 and 30 V for the others.
(2) Full range is –55°C to 125°C for LM158, –25°C to 85°C for LM258, and 0°C to 70°C for LM358, and –40°C to 125°C for LM2904 .
(3) All typical values are at T
A
= 25°C
4 Submit Documentation Feedback Copyright © 1976–2013, Texas Instruments Incorporated
Product Folder Links: LM158 LM258 LM258A LM358 LM358A LM2904 LM2904V