Figure 24. Adjustable Output Voltage Version
As in any switching regulator, layout is very important. Rapidly switching currents associated with wiring
inductance generate voltage transients which can cause problems. For minimal inductance and ground loops, the
length of the leads indicated by heavy lines should be kept as short as possible. Single-point grounding (as
indicated) or ground plane construction should be used for best results. When using the Adjustable version,
physically locate the programming resistors near the regulator, to keep the sensitive feedback wiring short.
Table 1. Inductor Selection by Manufacturer's Part Number
Inductor Value Pulse Eng. Renco NPI
68 μH * RL-1284-68-43 NP5915
100 μH * RL-1284-100-43 NP5916
150 μH 52625 RL-1284-150-43 NP5917
220 μH 52626 RL-1284-220-43 NP5918/5919
330 μH 52627 RL-1284-330-43 NP5920/5921
470 μH 52628 RL-1284-470-43 NP5922
680 μH 52629 RL-1283-680-43 NP5923
1000 μH 52631 RL-1283-1000-43 *
1500 μH * RL-1283-1500-43 *
2200 μH * RL-1283-2200-43 *
12 Submit Documentation Feedback Copyright © 1999–2013, Texas Instruments Incorporated