Table 41. READ_DIAGNOSTIC_WORD Format (continued)
Bit Meaning Default
9 TIMER_LATCHED_OFF 0
8 EXT_MOSFET_SHORTED 0
7 CONFIG_PRESET 1
6 DEVICE_OFF 1
5 VIN_UNDERVOLTAGE_FAULT 1
4 VIN_OVERVOLTAGE_FAULT 0
3 IIN_OC/PFET_OP_FAULT 0
2 OVER_TEMPERATURE_FAULT 0
1 CML_FAULT 0
0 CIRCUIT_BREAKER_FAULT 0
MFR_SPECIFIC_18: AVG_BLOCK_READ (E2h)
The AVG_BLOCK_READ command concatenates the DIAGNOSTIC_WORD with input and output average
telemetry information (IIN, VOUT, VIN, PIN) as well as TEMPERATURE to capture all of the operating
information of the part in a single PMBus™ transaction. The block is 12 bytes long with telemetry information
being sent out in the same manner as if an individual READ_AVG_XXX command had been issued (shown
below). AVG_BLOCK_READ also specifies that the VIN, VOUT, PIN, and IIN measurements are all time-aligned
whereas there is a chance they may not be if read with individual PMBus™ commands. To read data from the
AVG_BLOCK_READ command, use the SMBus Block Read protocol.
Table 42. AVG_BLOCK_READ Register Format
Byte Count (always 12) (1 byte)
DIAGNOSTIC_WORD (1 word)
AVG_IIN (1 word)
AVG_VOUT (1 word)
AVG_VIN (1 word)
AVG_PIN (1 word)
TEMPERATURE (1 word)