Waveforms
Conditions:
Input Voltage = 24VDC
Output Current = 10A
Bandwidth Limit = 20 MHz
Trace:
Output Ripple, Volts/div = 50 mV
Horizontal Resolution = 5.0 µs/div
Figure 5. Output Ripple
Figure 6 shows the transient response for a load of change from 5A to 10A. The upper trace shows
minimal output voltage droop and overshoot during the sudden change in output current shown by the
lower trace.
Conditions:
Input Voltage = 24VDC
Output Current = 5A to 10A
Bandwidth Limit = 20 MHz
Traces:
Bottom Trace: Output Current
Amps/div = 5A
Top Trace: Output Voltage response
Volts/div = 100 mV
Horizontal Resolution = 200 µs/div
Figure 6. Transient Response
Figure 7 and Figure 8 show the drain voltage of Q1 with a 5A load. Figure 7 represents drain voltage of
Q1 at an input voltage of 24V and Figure 8 represents drain voltage at an input voltage of 32V. Drain of
Q1 sees twice the input voltage when it is off and during dead-time it exactly sees input voltage.