Datasheet
www.ti.com
Electrical Characteristics
Switching Characteristics
LM211-EP
DIFFERENTIAL COMPARATOR WITH STROBES
SLCS140A – DECEMBER 2002 – REVISED MAY 2006
at specified free-air temperatures of Q and M temp ranges, V
CC+
= ± 15 V (unless otherwise noted)
PARAMETER TEST CONDITIONS T
A
(1)
MIN TYP
(2)
MAX UNIT
25 ° C 0.7 3
V
IO
Input offset voltage
(3)
mV
Full range 4
25 ° C 4 10
I
IO
Input offset current
(3)
nA
Full range 20
25 ° C 75 100
I
IB
Input bias current V
O
= 1 V to 14 V nA
Full range 150
I
IL(S)
Low-level strobe current
(4)
V
(strobe)
= 0.3 V, V
ID
≤ – 10 mV 25 ° C –3 mA
Common-mode input 13 to 13.8 to
V
ICR
Full range V
voltage range –14.5 –14.7
Large-signal differential
A
VD
V
O
= 5 V to 35 V, R
L
= 1 k Ω 25 ° C 40 200 V/mV
voltage amplification
I
(strobe)
= –3 mA, V
OH
= 35 V, 25 ° C 0.2 10 nA
High-level (collector)
I
OH
V
ID
= 5 mV
output leakage current
Full range 0.5 µ A
I
OL
= 50 mA, V
ID
= –5 mV 25 ° C 0.75 1.5
Low-level (collector-to-emitter)
V
OL
V
V
CC+
= 4.5 V, V
CC–
= 0,
output voltage
Full range 0.23 0.4
I
OL
= 8 mA, V
ID
= –6 mV
I
CC+
Supply current from V
CC+
, output low V
ID
= –10 mV, No load 25 ° C 5.1 6 mA
I
CC–
Supply current from V
CC–
, output high V
ID
= 10 mV, No load 25 ° C –4.1 –5 mA
(1) Unless otherwise noted, all characteristics are measured with BALANCE and BAL/STRB open and EMIT OUT grounded.
Full range is –40 ° C to 125 ° C for Q temp and -55 ° C to 125 ° C for M temp.
(2) All typical values are at T
A
= 25 ° C.
(3) The offset voltages and offset currents given are the maximum values required to drive the collector output up to 14 V or down to 1 V
with a pullup resistor of 7.5 k Ω to V
CC+
. These parameters actually define an error band and take into account the worst-case effects of
voltage gain and input impedance.
(4) The strobe should not be shorted to ground; it should be current driven at –3 mA to –5 mA (see Figure 13 and Figure 27 ).
V
CC+
= ± 15 V, T
A
= 25 ° C
PARAMETER TEST CONDITIONS TYP UNIT
Response time, low-to-high-level output R
C
= 500 Ω to 5 V, C
L
= 5 pF
(1)
115 ns
Response time, high-to-low-level output R
C
= 500 Ω to 5 V, C
L
= 5 pF
(1)
165 ns
(1) The response time specified is for a 100-mV input step with 5-mV overdrive and is the interval between the input step function and the
instant when the output crosses 1.4 V.
4
Submit Documentation Feedback