Datasheet
Table Of Contents

LM1876
www.ti.com
SNAS097C –MAY 1999–REVISED APRIL 2013
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
Absolute Maximum Ratings
(1)(2)(3)
Supply Voltage |V
CC
| + |V
EE
| (No Input) 64V
Supply Voltage |V
CC
| + |V
EE
| (with Input) 64V
Common Mode Input Voltage (V
CC
or V
EE
) and
|V
CC
| + |V
EE
| ≤ 54V
Differential Input Voltage 54V
Output Current Internally Limited
Power Dissipation
(4)
62.5W
ESD Susceptability
(5)
2000V
Junction Temperature
(6)
150°C
Thermal Resistance Isolated NDB-Package θ
JC
2°C/W
Non-Isolated NDL-Package θ
JC
1°C/W
Soldering Information NDB Package (10 sec.) 260°C
Storage Temperature −40°C to +150°C
(1) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is functional, but do not ensure specific performance limits. Electrical Characteristics state DC and AC electrical
specifications under particular test conditions which specify performance limits. This assumes that the device is within the Operating
Ratings. Specifications are not ensure for parameters where no limit is given, however, the typical value is a good indication of device
performance.
(2) All voltages are measured with respect to the GND pins (5, 10), unless otherwise specified.
(3) If Military/Aerospace specified devices are required, please contact the Texas Instruments Sales Office/ Distributors for availability and
specifications.
(4) For operating at case temperatures above 25°C, the device must be derated based on a 150°C maximum junction temperature and a
thermal resistance of θ
JC
= 2°C/W (junction to case) for the NDB package and θ
JC
= 1°C/W for the NDL package. Refer to
DETERMINING THE CORRECT HEAT SINK in Application Information.
(5) Human body model, 100 pF discharged through a 1.5 kΩ resistor.
(6) The operating junction temperature maximum is 150°C, however, the instantaneous Safe Operating Area temperature is 250°C.
Operating Ratings
(1)(2)
Temperature Range T
MIN
≤ T
A
≤ T
MAX
−20°C ≤ T
A
≤ +85°C
Supply Voltage |V
CC
| + |V
EE
|
(3)
20V to 64V
(1) All voltages are measured with respect to the GND pins (5, 10), unless otherwise specified.
(2) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is functional, but do not ensure specific performance limits. Electrical Characteristics state DC and AC electrical
specifications under particular test conditions which specify performance limits. This assumes that the device is within the Operating
Ratings. Specifications are not ensure for parameters where no limit is given, however, the typical value is a good indication of device
performance.
(3) Operation is specified up to 64V, however, distortion may be introduced from SPiKe Protection Circuitry if proper thermal considerations
are not taken into account. Refer to Application Information for a complete explanation.
Copyright © 1999–2013, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Links: LM1876