Datasheet

LM1875
SNAS524A MAY 2004REVISED MAY 2004
www.ti.com
Typical Applications
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
Absolute Maximum Ratings
(1)
Supply Voltage 60V
Input Voltage V
EE
to V
CC
Storage Temperature 65°C to + 150°C
Junction Temperature 150°C
(Soldering, 10 seconds) 260°C
Lead Temperature θ
JC
3°C
θ
JA
73°C
(1) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is functional, but do not ensure specific performance limits.
2 Submit Documentation Feedback Copyright © 2004, Texas Instruments Incorporated
Product Folder Links: LM1875