User's Manual
32
Micro-reader - Reference Guide May ’00
(hex)
0 01 Start Mark
1 05 Length Five bytes follow excluding BCC
2 6C Command Perform Single command, calculate FBCC,
Field (1) send Power Burst I & II with data
3 32 Data Field (1) Power Burst I with 50 ms duration (charge-up)
4 07 Data Field (2) Power Burst II with 15 ms duration (Progr. burst)
5 01 Data Field (3) One Data Field follows
6 0A Data Field (4) Write Address specifying Lock Page 2
7 5F BCC BCC over previous bytes excluding Start Mark
5.1.6 Selective Read Page of SAMPT
The following sequence of bytes reads page 2 of an SAMPT.
The 24 bit selective address = 12 34 56
MSByte LSByte
Byte Content Comment Description
(hex)
0 01 Start Mark
1 07 Length 7 bytes follow excluding BCC
2 4C Command Perform Single command, calculate FBCC,
Field (1) send Power Burst I with Data
3 32 Data Field (1) Power Burst I with 50 ms duration (charge-up)
4 04 Data Field (2) 4 Data Fields follow
5 0B Data Field (3) Write Address specifying selective Read Page 2
6 56 Data Field (4) Selective Address LSB
7 34 Data Field (5) Selective Address
8 12 Data Field (6) Selective Address MSB
9 06 BCC BCC over previous bytes excluding Start Mark
5.1.7 Selective Program Page of SAMPT
The following sequence of bytes selective programs page 2 of an SAMPT with:
00 00 00 00 00 00 00 11
MSByte LSByte
The 24 bit selective address = 12 34 56
MSByte LSByte
Byte Content Comment Description
(hex)
0 01 Start Mark
1 12 Length 18 bytes follow excluding BCC
2 6C Command Perform Single command, calculate FBCC,
Field (1) send Power Burst I & II with Data
3 32 Data Field (1) Power Burst I with 50 ms duration (charge-up)
4 0F Data Field (2) Power Burst II with 15 ms duration (Progr. burst)
5 0E Data Field (3) 14 Data Fields follow