Datasheet

LF155, LF156, LF355, LF356, LF357
SNOSBH0C MAY 2000REVISED MARCH 2013
www.ti.com
*
LF155/6 R = 5k, LF357 R = 1.25k
Figure 37. Driving Capacitive Loads
Due to a unique output stage design, these amplifiers have the ability to drive large capacitive loads and still
maintain stability. C
L(MAX)
0.01μF.
Overshoot 20%, Settling time (t
s
) 5μs
For distortion 1% and a 20 Vp-p V
OUT
swing, power bandwidth is: 500kHz.
Figure 38. LF357 - A Large Power BW Amplifier
Typical Applications
Figure 39. Settling Time Test Circuit
Settling time is tested with the LF155/6 connected as unity gain inverter and LF357 connected for A
V
= 5
FET used to isolate the probe capacitance
Output = 10V step
A
V
= 5 for LF357
14 Submit Documentation Feedback Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: LF155 LF156 LF355 LF356 LF357