Datasheet

LF353
JFET-INPUT
DUAL OPERATIONAL AMPLIFIER
SLOS012B – MARCH 1987 – REVISED AUGUST 1994
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
recommended operating conditions
MIN MAX
UNIT
Supply voltage, V
CC +
3.5 18 V
Supply voltage, V
CC –
3.5 –18 V
electrical characteristics over operating free-air temperature range, V
CC±
= ±15 V (unless
otherwise specified)
PARAMETER TEST CONDITIONS T
A
MIN TYP MAX UNIT
V
IO
In
p
ut offset voltage
V
IC
=0
R
S
=10k
25°C 5 10
mV
V
IO
Inp
u
t
offset
v
oltage
V
IC
=
0
,
R
S
=
10
k
Full range 13
mV
α
VIO
Average temperature coefficient of input offset
voltage
V
IC
= 0, R
S
= 10 k 10 µV/°C
I
IO
Inp t offset c rrent
V
IC
=0
25°C 25 100 pA
I
IO
I
nput o
ff
set current
V
IC
=
0
70°C 4 nA
I
IB
Inp t bias c rrent
V
IC
=0
25°C 50 200 pA
I
IB
I
nput
bi
as current
V
IC
=
0
70°C 8 nA
V
ICR
Common-mode input voltage range ±11
–12
to
15
V
V
OM
Maximum peak output voltage swing R
L
= 10 k ±12 ±13.5 V
A
VD
Large signal differential voltage
V
O
= ±10 V
R
L
=2k
25°C 25 100
V/mV
A
VD
Large
-
signal
differential
v
oltage
V
O
=
±10
V
,
R
L
=
2
k
Full range 15
V/mV
r
i
Input resistance T
J
= 25°C 10
12
CMRR Common-mode rejection ratio R
S
10 k 70 100 dB
k
SVR
Supply-voltage rejection ratio See Note 2 70 100 dB
I
CC
Supply current 3.6 6.5 mA
Full range is 0°C to 70°C.
Input bias currents of a FET-input operational amplifier are normal junction reverse currents, which are temperature sensitive. Pulse techniques
must be used that will maintain the junction temperatures as close to the ambient temperature as possible.
NOTE 2: Supply-voltage rejection ratio is measured for both supply magnitudes increasing or decreasing simultaneously.
operating characteristics, V
CC±
= ±15 V, T
A
= 25°C
PARAMETER TEST CONDITIONS MIN TYP MAX
UNIT
V
O1
/V
O2
Crosstalk attentuation f = 1 kHz 120 dB
SR Slew rate 8 13 V/µs
B
1
Unity-gain bandwidth 3 MHz
V
n
Equivalent input noise voltage f = 1 kHz, R
S
= 20 18 nV/Hz
I