Datasheet

TMS570LS1224
www.ti.com
SPNS190B OCTOBER 2012REVISED FEBRUARY 2015
NOTE
A device must internally provide a hold time of at least 300 ns for the SDA signal
(referred to the VIHmin of the SCL signal) to bridge the undefined region of the falling
edge of SCL.
The maximum t
h(SDA-SCLL)
has only to be met if the device does not stretch the LOW
period (t
w(SCLL)
) of the SCL signal.
A Fast-mode I2C-bus device can be used in a Standard-mode I2C-bus system, but the
requirement t
su(SDA-SCLH)
250 ns must then be met. This will automatically be the case if
the device does not stretch the LOW period of the SCL signal. If such a device does
stretch the LOW period of the SCL signal, it must output the next data bit to the SDA line
tr max + t
su(SDA-SCLH)
.
C
b
= total capacitance of one bus line in pF. If mixed with fast-mode devices, faster fall-
times are allowed.
Copyright © 2012–2015, Texas Instruments Incorporated Peripheral Information and Electrical Specifications 141
Submit Documentation Feedback
Product Folder Links: TMS570LS1224