Datasheet
www.ti.com
STC Module Assignments
10.2 STC Module Assignments
There are two instances of STC modules available on this device, see Table 10-1. STC1 is used for
running self-test on the redundant CPUs and µSCU. STC2 is used for running self-test on the two nHET
modules. The two instances are independent of each other.
Table 10-1. STC Module Assignments
Number of STCCLK Derived
Module Segments Targeted IP Intervals From Note
STC1 Segment 0 CPU1 and CPU2 125 GCLK Segment 0 allows CPU1 and
CPU2 to be tested in parallel
or individually.
Segment 1 µSCU (ACP Block) 3 GCLK
STC2 Segment 0 nHET1 and nHET2 57 VCLK2 Segment 0 allows nHET1 and
nHET2 to be tested in parallel
or individually.
419
SPNU562–May 2014 Self-Test Controller (STC) Module
Submit Documentation Feedback
Copyright © 2014, Texas Instruments Incorporated