4.2.1.9 Controller Area Network Controllers (DCAN)
Table 4-9. ZWT Controller Area Network Controllers (DCAN)
Terminal
Signal
Type
Default Pull
State
Pull Type
Output
Buffer
Drive
Strength
Description
Signal Name
337
ZWT
DCAN1RX B10 I/O Pullup Programmable,
20 µA
2mA ZD CAN1 receive, or GIO
DCAN1TX A10 I/O Pullup Programmable,
20 µA
2mA ZD CAN1 transmit, or GIO
DCAN2RX H1 I/O Pullup Programmable,
20 µA
2mA ZD CAN2 receive, or GIO
DCAN2TX H2 I/O Pullup Programmable,
20 µA
2mA ZD CAN2 transmit, or GIO
DCAN3RX M19 I/O Pullup Programmable,
20 µA
2mA ZD CAN3 receive, or GIO
DCAN3TX M18 I/O Pullup Programmable,
20 µA
2mA ZD CAN3 transmit, or GIO
GIOB[3]/DCAN4RX W10 I/O Pulldown Programmable,
20 µA
2mA ZD CAN4 receive, or GIO
GIOB[2]/DCAN4TX F2 I/O Pulldown Programmable,
20 µA