Datasheet

EPWM2SYNCI
ePWM2
EPWM2SYNCO
EPWM1SYNCO
ePWM1
EPWM1SYNCI
GPIO
MUX
EPWM3SYNCO
ePWM3
EPWM3SYNCI
ePWMx
EPWMxSYNCI
SYNCI
eCAP1
EPWMxSYNCO
www.ti.com
ePWM Submodules
The proper procedure for enabling ePWM clocks is as follows:
1. Enable ePWM module clocks using the IOMM control registers for each ePWM module instance
2. Set TBCLKSYNC = 0. This will stop the time-base clock within any enabled ePWM module.
3. Configure ePWM modules: prescaler values and ePWM modes.
4. Set TBCLKSYNC = 1.
34.2.2.3.3 Time-Base Counter Synchronization
A time-base synchronization scheme connects all of the ePWM modules on a device. Each ePWM
module has a synchronization input (EPWMxSYNCI) and a synchronization output (EPWMxSYNCO). The
input synchronization for the first instance (ePWM1) comes from an external pin. The synchronization
connections for the remaining ePWM modules are shown in Figure 34-6.
Figure 34-6. Time-Base Counter Synchronization Scheme
1723
SPNU562May 2014 Enhanced Pulse Width Modulator (ePWM) Module
Submit Documentation Feedback
Copyright © 2014, Texas Instruments Incorporated