Datasheet

192
RM57L843
SPNS215C FEBRUARY 2014REVISED JUNE 2016
www.ti.com
Submit Documentation Feedback
Product Folder Links: RM57L843
Peripheral Information and Electrical Specifications Copyright © 2014–2016, Texas Instruments Incorporated
Table 7-32. MIBSPI3 Event Trigger Hookup (continued)
Event # TGxCTRL TRIGSRC[3:0] Trigger
EVENT9 1010 N2HET1[10]
EVENT10 1011 N2HET1[12]
EVENT11 1100 N2HET1[14]
EVENT12 1101 N2HET1[16]
EVENT13 1110 N2HET1[18]
EVENT14 1111 Intern Tick counter
NOTE
For N2HET1 trigger sources, the connection to the MibSPI3 module trigger input is made
from the input side of the output buffer (at the N2HET1 module boundary). This way, a
trigger condition can be generated even if the N2HET1 signal is not selected to be output on
the pad.
NOTE
For GIOx trigger sources, the connection to the MibSPI3 module trigger input is made from
the output side of the input buffer. This way, a trigger condition can be generated either by
selecting the GIOx pin as an output pin plus selecting the pin to be a GIOx pin, or by driving
the GIOx pin from an external trigger source. If the mux control module is used to select
different functionality instead of the GIOx signal, then care must be taken to disable GIOx
from triggering MibSPI3 transfers; there is no multiplexing on the input connections.