32.5.3 Capture-1 Register (CAP1)
NOTE: In APWM mode, writing to CAP1/CAP2 active registers also writes the same value to the
corresponding shadow registers CAP3/CAP4. This emulates immediate mode. Writing to the
shadow registers CAP3/CAP4 invokes the shadow mode.
Figure 32-16. Capture-1 Register (CAP1) [offset = 08h]
31 0
CAP1
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 32-4. Capture-1 Register (CAP1) Field Descriptions
Bits Field Description
31-0 CAP1 This register can be loaded (written) by :
Time-Stamp (counter value) during a capture event
Software - may be useful for test purposes / initialization
APRD shadow register (CAP3) when used in APWM mode
32.5.4 Capture-2 Register (CAP2)
NOTE: In APWM mode, writing to CAP1/CAP2 active registers also writes the same value to the
corresponding shadow registers CAP3/CAP4. This emulates immediate mode. Writing to the
shadow registers CAP3/CAP4 invokes the shadow mode.
Figure 32-17. Capture-2 Register (CAP2) [offset = 0Ch]
31 0
CAP2
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 32-5. Capture-2 Register (CAP2) Field Descriptions
Bits Field Description
31-0 CAP2 This register can be loaded (written) by:
Time-Stamp (counter value) during a capture event
Software - may be useful for test purposes
APRD shadow register (CAP4) when used in APWM mode