Datasheet

ECAPx
PSout
div 2
PSout
div 4
PSout
div 6
PSout
div 8
PSout
div 10
0
1
/n
5
ECCTL1[EVTPS]
prescaler [5 bits]
(counter)
By−pass
Event prescaler
ECAPx pin
(from GPIO)
PSout
Basic Operation
www.ti.com
Figure 32-3. Event Prescale Control
A When a prescale value of 1 is chosen (ECCTL1[13:9] = 0,0,0,0,0 ), the input capture signal by-passes the prescale
logic completely.
Figure 32-4. Prescale Function Waveforms
32.2.2.2 Edge Polarity Select and Qualifier
Four independent edge polarity (rising edge/falling edge) selection MUXes are used, one for each
capture event.
Each edge (up to 4) is event qualified by the Modulo4 sequencer.
The edge event is gated to its respective CAPx register by the Mod4 counter. The CAPx register is
loaded on the falling edge.
1648
Enhanced Capture (eCAP) Module SPNU562May 2014
Submit Documentation Feedback
Copyright © 2014, Texas Instruments Incorporated