Datasheet
www.ti.com
SCI/LIN Control Registers
Table 28-12. SCI Global Control Register 1 (SCIGCR1) Field Descriptions (continued)
Bit Field Value Description
0 COMM MODE SCI/LIN communication mode bit. In compatibility mode it selects the SCI communication mode.
In LIN mode it selects length control option for ID-field bits ID4 and ID5.
SCI mode:
0 Idle-line mode is used.
1 Address-bit mode is used.
LIN mode:
0 ID4 and ID5 are not used for length control.
1 ID4 and ID5 are used for length control.
Table 28-13. SCI Receiver Status Flags
SCI Flag Register Bit Value After SW nRESET
(1)
CE SCIFLR 29 0
ISFE SCIFLR 28 0
NRE SCIFLR 27 0
FE SCIFLR 26 0
OE SCIFLR 25 0
PE SCIFLR 24 0
RXWAKE SCIFLR 12 0
RXRDY SCIFLR 9 0
BUSY SCIFLR 3 0
IDLE SCIFLR 2 0
WAKE UP SCIFLR 1 0
BRKDT SCIFLR 0 0
(1)
The flags are frozen with their reset value while SW nRESET = 0.
Table 28-14. SCI Transmitter Status Flags
SCI Flag Register Bit Value After SW nRESET
(1)
BE SCIFLR 31 0
PBE SCIFLR 30 0
TX WAKE SCIFLR 10 0
TX EMPTY SCIFLR 11 1
TXRDY SCIFLR 8 1
(1)
The flags are frozen with their reset value while SW nRESET = 0.
1393
SPNU562–May 2014 Serial Communication Interface (SCI)/Local Interconnect Network (LIN)
Module
Submit Documentation Feedback
Copyright © 2014, Texas Instruments Incorporated