SCI/LIN Control Registers
28.7.1 SCI Global Control Register 0 (SCIGCR0)
The SCIGCR0 register defines the module reset. Figure 28-28 and Table 28-11 illustrate this register.
Figure 28-28. SCI Global Control Register 0 (SCIGCR0) (offset = 00)
31 16
Reserved
R-0
15 1 0
Reserved RESET
R-0 R/WP-0
LEGEND: R = Read only; R/WP = Read/Write in privileged mode only; -n = value after reset
Table 28-11. SCI Global Control Register 0 (SCIGCR0) Field Descriptions
Bit Field Value Description
31-1 Reserved 0 Read returns 0. Writes have no effect.
0 RESET This bit resets the SCI/LIN module. This bit is effective in SCI and LIN mode.
0 SCI/LIN module is in reset.
1 SCI/LIN module is out of reset.
Note: Read/Write in privileged mode only.