DCAN Control Registers
Table 26-24. IF1/IF2 Command Register Field Descriptions
Bit Field Value Description
31-24 Reserved 0 These bits are always read as 0. Writes have no effect.
23 WR/RD Write/Read
0 Direction = Read: Transfer direction is from the message object addressed by Message
Number (Bits [7:0]) to the IF1/IF2 register set
1 Direction = Write: Transfer direction is from the IF1/IF2 register set to the message object
addressed by Message Number (Bits [7:0])
22 Mask Access Mask bits
0 Mask bits will not be changed
1 Direction = Read: The Mask bits (Identifier Mask + MDir + MXtd) will be transferred from the
message object addressed by Message Number (Bits [7:0]) to the IF1/IF2 Register set.
Direction = Write: The Mask bits (Identifier Mask + MDir + MXtd) will be transferred from the
IF1/IF2 Register set to the message object addressed by Message Number (Bits [7:0])
21 Arb Access Arbitration bits
0 Arbitration bits will not be changed
1 Direction = Read: The Arbitration bits (Identifier + Dir + Xtd + MsgVal) will be transferred from
the message object addressed by Message Number (Bits [7:0]) to the corresponding IF1/IF2
Register set
Direction = Write: The Arbitration bits (Identifier + Dir + Xtd + MsgVal) will be transferred from
the IF1/IF2 Register set to the message object addressed by Message Number (Bits [7:0])
20 Control Access Control bits
0 Control bits will not be changed
1 Direction = Read: The Message Control bits will be transferred from the message object
addressed by Message Number (Bits [7:0]) to the corresponding IF1/IF2 Register set
Direction = Write: The Message Control bits will be transferred from the IF1/IF2 Register set to
the message object addressed by Message Number (Bits [7:0])
If the TxRqst/NewDat bit in this register (Bit [18]) is set, the TxRqst/NewDat bit in the IF1/IF2
Message Control Register will be ignored
19 ClrIntPnd Clear Interrupt Pending bit
0 IntPnd bit will not be changed
1 Direction = Read: Clears IntPnd bit in the message object
Direction = Write: This bit is ignored. Copying of IntPnd flag from IF1/IF2 Registers to Message
RAM can be controlled by only the Control flag (Bit [20])
18 TxRqst/NewDat Access Transmission Request bit
0 Direction = Read: NewDat bit will not be changed.
Direction = Write: TxRqst/NewDat bit will be handled according to the Control bit
1 Direction = Read: Clears NewDat bit in the message object.
Direction = Write: Sets TxRqst/NewDat in the message object
Note: If a CAN transmission is requested by setting TxRqst/NewDat in this register, the
TxRqst/NewDat bits in the message object will be set to 1 and independent of the values in
IF1/IF2 Message Control Register.
A read access to a message object can be combined with the reset of the control bits IntPnd
and NewDat. The values of these bits transferred to the IF1/IF2 Message Control Register
always reflect the status before resetting them.
17 Data A Access Data Bytes 0–3
0 Data Bytes 0–3 will not be changed
1 Direction = Read: The Data Bytes 0–3 will be transferred from the message object addressed
by the Message Number (Bits [7:0]) to the corresponding IF1/IF2 Register set
Direction = Write: The Data Bytes 0–3 will be transferred from the IF1/IF2 Register set to the
message object addressed by the Message Number (Bits [7:0])
Note: The duration of the message transfer is independent of the number of bytes to be
transferred.