26.17.9 ECC Diagnostic Status Register (DCAN ECCDIAG STAT)
Figure 26-28. ECC Diagnostic Status Register (DCAN ECCDIAG STAT) [offset = 28h]
31 16
Reserved
R-0
15 9 8 7 1 0
Reserved DEFLG DIAG Reserved SEFLG DIAG
R-0 R-0 R-0 R-0
LEGEND: R = Read only; -n = value after reset; U = Undefined
Table 26-15. ECC Diagnostic Status Register (DCAN ECCDIAG STAT) Field Descriptions
Bit Field Value Description
31-9 Reserved 0 These bits are always read as 0. Writes have no effect.
8 DEFLG DIAG Double bit error flag diagnostic
0
Read: No double bit error detected.
Write: The bit is unchanged.
1
Read: Double bit error detected in diagnostic mode.
Write: The bit is cleared to 0.
7-1 Reserved 0 These bits are always read as 0. Writes have no effect.
0 SEFLG DIAG Single bit error flag diagnostic
0
Read: No single bit error detected.
Write: The bit is unchanged.
1
Read: Single bit error detected in diagnostic mode
Write: The bit is cleared to 0.
1192