Datasheet
www.ti.com
HTU Control Registers
24.4.23 Module Identification Register (HTU ID)
This register is for TI internal purposes and allows to keep track of the HTU module version on different
devices.
Figure 24-36. Module Identification Register (HTU ID) [offset = 60h]
31 24 23 16
Reserved CLASS
R-0 R - Module Class Number
15 8 7 0
TYPE REV
R - Class Subtype Number R - Module Revision Number
LEGEND: R = Read only; -n = value after reset
Table 24-36. Module Identification Register (HTU ID) Field Descriptions
Bit Field Value Description
31-24 Reserved 0 Read returns 0. Writes have no effect.
23-16 CLASS Module Class
This field defines the module class number as read-only constant value for the HTU module.
Writes have no effect.
15-8 TYPE Subtype within a Class
This field defines the subtype within a class as read-only constant value for the HTU module.
Writes have no effect.
7-0 REV Module Revision Number
This field defines the module revision number as read-only constant value for the HTU module.
Writes have no effect.
1101
SPNU562–May 2014 High-End Timer Transfer Unit (HTU) Module
Submit Documentation Feedback
Copyright © 2014, Texas Instruments Incorporated