Datasheet
HTU Control Registers
www.ti.com
24.4.15 Request Lost Flag Register (HTU RLOSTFL)
Figure 24-28. Request Lost Flag Register (HTU RLOSTFL) [offset = 40h]
31 16
Reserved
R-0
15 0
CPRLFL
R/WPC-0
LEGEND: R/W = Read/Write; R = Read only; WPC = Write 1 in privilege mode to clear the bit; -n = value after reset
Table 24-28. Request Lost Flag Register (HTU RLOSTFL) Field Descriptions
Bit Field Value Description
31-16 Reserved 0 Read returns 0. Writes have no effect.
15-0 CPRLFL CP Request Lost Flags
0 No request was lost. Writing a zero has no effect.
1 If bit (2*x) is set, a request was lost on CP A of DCP x.
If bit (2*x+1) is set, a request was lost on CP B of DCP x. Reading from INTOFFx in case of a
RLOST interrupt clears the corresponding flag. The state of the flag bit can be polled even if
RLINTENA is cleared.
• Reading CPRLFL will not clear the flags or
• Reading from INTOFFx clears the corresponding flag.
• Writing a one clears the corresponding flag.
24.4.16 Buffer Full Interrupt Flag Register (HTU BFINTFL)
Figure 24-29. Buffer Full Interrupt Flag Register (HTU BFINTFL) [offset = 44h]
31 16
Reserved
R-0
15 0
BFINTFL
R/WPC-0
LEGEND: R/W = Read/Write; R = Read only; WPC = Write 1 in privilege mode to clear the bit; -n = value after reset
Table 24-29. Buffer Full Interrupt Flag Register (HTU BFINTFL) Field Descriptions
Bit Field Value Description
31-16 Reserved 0 Read returns 0. Writes have no effect.
15-0 BFINTFL Buffer Full Interrupt Flags
0 No buffer full condition detected. Writing a zero has no effect.
1 If bit (2*x) is set, a buffer full condition on CP A of DCP x has been detected.
If bit (2*x+1) is set, a buffer full condition on CP B of DCP x has been detected.
The BFINTFL flag is set after the last frame finishes on the corresponding buffer regardless of
whether the buffer is configured to one shot, circular or auto-switch mode. If BFINTFL is set in
circular mode, then a circular overrun has occurred on the corresponding buffer. This can be used
to indicate whether the buffer section after the frozen full address contains valid data or not.
Reading from INTOFFx in case of a buffer-full interrupt clears the corresponding flag. The state of
the flag bit can be polled even if the corresponding interrupt enable bit is cleared.
• Reading BFINTFL will not clear the flags or
• Reading INTOFFx will clear the corresponding flags or
• Writing a one clears the corresponding flag.
1096
High-End Timer Transfer Unit (HTU) Module SPNU562–May 2014
Submit Documentation Feedback
Copyright © 2014, Texas Instruments Incorporated