Datasheet

130
RM57L843
SPNS215C FEBRUARY 2014REVISED JUNE 2016
www.ti.com
Submit Documentation Feedback
Product Folder Links: RM57L843
System Information and Electrical Specifications Copyright © 2014–2016, Texas Instruments Incorporated
Table 6-45. ESM Channel Assignments (continued)
ESM ERROR SOURCES GROUP CHANNELS
Reserved Group2 12
Reserved Group2 13
Reserved Group2 14
Reserved Group2 15
Reserved Group2 16
L2FMC - parity error
Mcmd parity error on Idle command
POM idle state parity error
Port A/B Idle state parity error
Group2 17
Reserved Group2 18
L2FMC - double bit ECC error-error due to implicit OTP reads Group2 19
Reserved Group2 20
EPC - Uncorrectable Error Group2 21
Reserved Group2 22
Reserved Group2 23
RTI_WWD_NMI Group2 24
CCM-R5F VIM compare error Group2 25
CPU1 AXIM Bus Monitor failure Group2 26
Reserved Group2 27
CCM-R5F - Power Domain monitor error Group2 28
Reserved Group2 29
Reserved Group2 30
Reserved Group2 31
Group3
Reserved Group3 0
eFuse Farm - autoload error Group3 1
Reserved Group3 2
L2RAMW - double bit ECC uncorrectable error Group3 3
Reserved Group3 4
Reserved Group3 5
Reserved Group3 6
Reserved Group3 7
Reserved Group3 8
Cortex-R5F Core - All fatal events (OR of:
Group3 9
Event Reference
Value
Event Description EVNTBUSm Bit
0x60 Data Cache 33
0x61 Data Cache tag/dirty 34
Reserved Group3 10
Reserved Group3 11
CPU Interconnect Subsystem - Diagnostic Error Group3 12
L2FMC - uncorrectable error due to:
address parity/internal parity error
address tag
internal switch time-out
Group3 13
L2RAMW - Uncorrectable error Type A Group3 14
L2RAMW - Address/Control parity error Group3 15
Reserved Group3 16