Datasheet
+
=
Minimum offset
Immediate DF
Remote DF
25 bits
25-bit addition
32 bits
HR
HR
+
=
Remote DF
Immediate DF
Remote DF
32 bits
LSBs (HR data field)
25-bit addition
HR
HR
www.ti.com
Instruction Set
Figure 23-77 andFigure 23-78 illustrate the behavior of ADCNST if the remote data field is or is not zero.
Figure 23-77. ADCNST Operation If Remote Data Field[31:7] Is Not Zero
Figure 23-78. ADCNST Operation if Remote Data Field [31:7] Is Zero
Execution
If (Remote Data Field Value [31:7] != 0)
Remote Data Field = Immediate Data Field + Remote Data Field;
else
Remote Data Field = Immediate Data Field + min. offset(bits C24:C0);
Jump to Next Program Address;
1005
SPNU562–May 2014 High-End Timer (N2HET) Module
Submit Documentation Feedback