Datasheet

www.ti.com
N2HET Control Registers
23.4.31 Loop Back Pair Select Register (HETLBPSEL)
Refer to Section 23.2.5.7 for a description of loopback test functions.
N2HET1: offset = FFF7 B88Ch; N2HET2: offset = FFF7 B98Ch
Figure 23-65. Loop Back Pair Select Register (HETLBPSEL)
31 30 29 28 27 26 25 24
LBPTYPE31/30 LBPTYPE29/28 LBPTYPE27/26 LBPTYPE25/24 LBPTYPE23/22 LBPTYPE21/20 LBPTYPE19/18 LBPTYPE17/16
R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0
23 22 21 20 19 18 17 16
LBPTYPE15/14 LBPTYPE13/12 LBPTYPE11/10 LBPTYPE9/8 LBPTYPE7/6 LBPTYPE5/4 LBPTYPE3/2 LBPTYPE1/0
R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0
15 14 13 12 11 10 9 8
LBPSEL 31/30 LBPSEL 29/28 LBPSEL 27/26 LBPSEL 25/24 LBPSEL 23/22 LBPSEL 21/20 LBPSEL 19/18 LBPSEL 17/16
R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0
7 6 5 4 3 2 1 0
LBPSEL 15/14 LBPSEL 13/12 LBPSEL 11/10 LBPSEL 9/8 LBPSEL 7/6 LBPSEL 5/4 LBPSEL 3/2 LBPSEL 1/0
R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 23-46. Loop Back Pair Select Register (HETLBPSEL) Field Descriptions
Bit Field Value Description
31-16 LBPTYPE Loop Back Pair Type Select Bits
n+1 / n
These bits are valid only when Loopback mode is enabled (HETLBPDIR[19:16] = "1010").
0 Digital loopback is selected for HR structures on pins HET[n+1] and HET[n].
1 Analog loopback is selected for HR structures on pins HET[n+1] and HET[n].
15-0 LBPSEL Loop Back Pair Select Bits
n+1 / n
These bits are valid only when Loopback mode is enabled (HETLBPDIR[19:16] = "Ah").
If bit x is set, the HR structures on pins HET[n+1] and HET[n] are connected in a loop back mode.
The direction is given by LBPDIR n+1/n and type is selected by LBPTYPE n+1/n.
The pin which is not driven by the N2HET pin actions can still be used as normal GIO pin.