Datasheet

Table Of Contents
RM46L852
www.ti.com
SPNS185C SEPTEMBER 2012REVISED JUNE 2015
4.3.2.16 System Module Interface
Table 4-43. ZWT System Module Interface
Terminal Signal Reset Pull Pull Type Description
Type State
Signal Name 337
ZWT
nPORRST W7 Input Pulldown Fixed 100 µA Power-on reset, cold reset
Pulldown External power supply
monitor circuitry must
drive nPORRST low when
any of the supplies to the
microcontroller fall out of
the specified range. This
terminal has a glitch filter.
See Section 6.8.
nRST B17 I/O Pullup Fixed 100 µA System reset, warm reset,
Pullup bidirectional.
The internal circuitry
indicates any reset
condition by driving nRST
low.
The external circuitry can
assert a system reset by
driving nRST low. To
ensure that an external
reset is not arbitrarily
generated, TI
recommends that an
external pullup resistor is
connected to this terminal.
This terminal has a glitch
filter. See Section 6.8.
nERROR B14 I/O Pulldown Fixed 20 µA ESM Error Signal
Pulldown Indicates error of high
severity. See
Section 6.18.
4.3.2.17 Clock Inputs and Outputs
Table 4-44. ZWT Clock Inputs and Outputs
Terminal Signal Reset Pull Pull Type Description
Type State
Signal Name 337
ZWT
OSCIN K1 Input N/A None From external
crystal/resonator, or
external clock input
KELVIN_GND L2 Input Kelvin ground for oscillator
OSCOUT L1 Output To external
crystal/resonator
ECLK A12 I/O Pulldown Programmable, External prescaled clock
20 µA output, or GIO.
GIOA[5]/EXTCLKIN/EPWM1A/N2HET1_PIN_nDIS B5 Input Pulldown 20 µA External clock input #1
EXTCLKIN2 R9 Input External clock input #2
VCCPLL P11 1.2V N/A None Dedicated core supply for
Power PLL's
Copyright © 2012–2015, Texas Instruments Incorporated Terminal Configuration and Functions 45
Submit Documentation Feedback
Product Folder Links: RM46L852