Datasheet

Table Of Contents
RM46L852
SPNS185C SEPTEMBER 2012 REVISED JUNE 2015
www.ti.com
4.3.1.15 System Module Interface
Table 4-18. PGE System Module Interface
Terminal Signal Reset Pull Pull Type Description
Type State
Signal Name 144
PGE
nPORRST 46 Input Pulldown Fixed 100 µA Power-on reset, cold reset
Pulldown External power supply
monitor circuitry must
drive nPORRST low when
any of the supplies to the
microcontroller fall out of
the specified range. This
terminal has a glitch filter.
See Section 6.8.
nRST 116 I/O Pullup Fixed 100 µA System reset, warm reset,
Pullup bidirectional.
The internal circuitry
indicates any reset
condition by driving nRST
low.
The external circuitry can
assert a system reset by
driving nRST low. To
ensure that an external
reset is not arbitrarily
generated, TI
recommends that an
external pullup resistor is
connected to this terminal.
This terminal has a glitch
filter. See Section 6.8.
nERROR 117 I/O Pulldown Fixed 20 µA ESM Error Signal
Pulldown Indicates error of high
severity. See
Section 6.18.
4.3.1.16 Clock Inputs and Outputs
Table 4-19. PGE Clock Inputs and Outputs
Terminal Signal Reset Pull Pull Type Description
Type State
Signal Name 144
PGE
OSCIN 18 Input N/A None From external
crystal/resonator, or
external clock input
KELVIN_GND 19 Input Kelvin ground for oscillator
OSCOUT 20 Output To external
crystal/resonator
ECLK 119 I/O Pulldown Programmable, External prescaled clock
20 µA output, or GPIO.
GIOA[5]/EXTCLKIN/EPWM1A /N2HET1_PIN_nDIS 14 Input Pulldown Fixed 20 µA External clock input #1
Pulldown
24 Terminal Configuration and Functions Copyright © 2012–2015, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: RM46L852