Table 26-153. New Data Registers (NDATn) Field Descriptions
Bit Field Value Description
127-0 ND New data.
0 The flags are reset when the header section of the corresponding message buffer is reconfigured or
when the data section has been transferred to the output buffer.
1 The flags are set when a valid received data frame matches the message buffer's filter configuration,
independent of the payload length received or the payload length configured for that message buffer.
The flags are not set after reception of null frames except for message buffers belonging to the receive
FIFO.