Datasheet

www.ti.com
FlexRay Module Registers
NOTE: CHI command RESET_STATUS_INDICATORS (SUCC1.CMD = Ah) resets flags FSI, HRQ,
CSNI, CSAI, the slot mode SLM, and the wakeup status WSV.
26.3.2.4.2 Communication Controller Error Vector (CCEV)
Reset by CHI command RESET_STATUS_INDICATORS or by transition from HALT to
DEFAULT_CONFIG state or when entering READY state.
Figure 26-147 and Table 26-132 illustrate this register.
Figure 26-147. Communication Controller Error Vector Register (CCEV) [offset_CC = 104h]
31 16
Reserved
R-0
15 13 12 8 7 6 5 4 3 0
Reserved PTAC ERRM Reserved CCFC
R-0 R-0 R-0 R-0 R-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 26-132. Communication Controller Error Vector Register (CCEV) Field Descriptions
Bit Field Value Description
31-13 Reserved 0 Read returns 0. Writes have no effect.
12-8 PTAC 0-1Fh Passive to active count. Indicates the number of consecutive even / odd cycle pairs that have
passed with valid rate and offset correction terms, while the node is waiting to transit from
NORMAL_PASSIVE state to NORMAL_ACTIVE state. The transition takes place when PTAC
equals PTA - 1 as defined in the SUC configuration register 1.
7-6 ERRM Error mode. Indicates the actual error mode of the POC.
0 ACTIVE
1h PASSIVE
2h COMM_HALT
3h Reserved
5-4 Reserved 0 Read returns 0. Writes have no effect.
3-0 CCFC 0-Fh Clock correction failed counter. The clock correction failed counter is incremented by one at the
end of any odd communication cycle where either the missing offset correction error or missing
rate correction error are active. The clock correction failed counter is reset to 0 at the end of an
odd communication cycle if neither the offset correction failed nor the rate correction failed errors
are active. The clock correction failed counter stops at 15.
1319
SPNU563May 2014 FlexRay Module
Submit Documentation Feedback
Copyright © 2014, Texas Instruments Incorporated