Datasheet

www.ti.com
FlexRay Module Registers
MONITOR_MODE
Enter MONITOR_MODE when called in POC state CONFIG. In this mode the communication controller is
able to receive FlexRay frames and CAS / MTS symbols. It is also able to detect coding errors. The
temporal integrity of received frames is not checked. This mode can be used for debugging purposes, for
example, in case that the startup of a FlexRay network fails. When called in any other state, CMD will be
reset to 0000 = command_not_accepted.
26.3.2.3.2 SUC Configuration Register 2 (SUCC2)
The communication controller accepts modifications of the register in DEFAULT_CONFIG or CONFIG
state only.
Figure 26-129 and Table 26-114 illustrate this register.
Figure 26-129. SUC Configuration Register 2 (SUCC2) [offset_CC = 84h]
31 28 27 24 23 21 20 16
Reserved LTN* Reserved LT*
R-0 R/W-1h R-0 R/W-504h
15 0
LT*
R/W-504h
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset; *These bits can be updated in DEFAULT_CONFIG or CONFIG state
only.
Table 26-114. SUC Configuration Register 2 (SUCC2) Field Descriptions
Bit Field Value Description
31-28 Reserved. 0 Reads return 0. Writes have no effect.
27-24 LTN 2-Fh Listen timeout noise. Configures the upper limit for the startup and wakeup listen timeout in the
presence of noise. Must be identical in all nodes of a cluster.
The wakeup / startup noise timeout is calculated as follows: LT· (LTN + 1)
23-21 Reserved. 0 Reads return 0. Writes have no effect.
20-0 LT 504h-139706h µT Listen timeout. Configures the upper limit of the startup and wakeup listen timeout.
1305
SPNU563May 2014 FlexRay Module
Submit Documentation Feedback
Copyright © 2014, Texas Instruments Incorporated