Datasheet
FlexRay Module Registers
www.ti.com
26.3.2.2.7 Interrupt Line Enable Register (ILE)
Each of the two interrupt lines (CC_int0, CC_int1) can be enabled / disabled separately by programming
bit EINT0 and EINT1.
Figure 26-123 and Table 26-108 illustrate this register.
Figure 26-123. Interrupt Line Enable Register (ILE) [offset_CC = 40h]
31 16
Reserved
R-0
15 2 1 0
Reserved EINT
R-0 R/W-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 26-108. Interrupt Line Enable Register (ILE) Field Descriptions
Bit Field Value Description
31-2 Reserved 0 Read returns 0. Writes have no effect.
1-0 EINT Enable interrupt line (1-0).
0 Interrupt line CC_int1 and CC_int0 disabled
1h Interrupt line CC_int1 disabled and CC_int0 enabled
2h Interrupt line CC_int1 enabled and CC_int0 disabled
3h Interrupt line CC_int1 and CC_int0 enabled
1296
FlexRay Module SPNU563–May 2014
Submit Documentation Feedback
Copyright © 2014, Texas Instruments Incorporated