Datasheet
FlexRay Module Registers
www.ti.com
Table 26-96. ECC Diagnostic Status Register (ECCDSTAT) Field Descriptions (continued)
Bit Field Value Description
16 DEFA ECC Double Bit Error Flag for Input Buffer 1 RAM.
0 No ECC double bit error is detected.
1 ECC double bit error is detected and diagnostic mode is enabled.
15-8 Reserved 0 Read returns 0. Writes have no effect.
7 SEFH ECC Single Bit Error Flag for FTU RAM.
0 No ECC single bit error is detected.
1 ECC single bit error is detected and diagnostic mode is enabled.
6 SEFG ECC Single Bit Error Flag for FlexRay Message RAM.
0 No ECC single bit error is detected.
1 ECC single bit error is detected and diagnostic mode is enabled.
5 SEFF ECC Single Bit Error Flag for Transient Buffer B RAM.
0 No ECC single bit error is detected.
1 ECC single bit error is detected and diagnostic mode is enabled.
4 SEFE ECC Single Bit Error Flag for Transient Buffer A RAM.
0 No ECC single bit error is detected.
1 ECC single bit error is detected and diagnostic mode is enabled.
3 SEFD ECC Single Bit Error Flag for Output Buffer 2 RAM.
0 No ECC single bit error is detected.
1 ECC single bit error is detected and diagnostic mode is enabled.
2 SEFC ECC Single Bit Error Flag for Output Buffer 1 RAM.
0 No ECC single bit error is detected.
1 ECC single bit error is detected and diagnostic mode is enabled.
1 SEFB ECC Single Bit Error Flag for Input Buffer 2 RAM.
0 No ECC single bit error is detected.
1 ECC single bit error is detected and diagnostic mode is enabled.
0 SEFA ECC Single Bit Error Flag for Input Buffer 1 RAM.
0 No ECC single bit error is detected.
1 ECC single bit error is detected and diagnostic mode is enabled.
1272
FlexRay Module SPNU563–May 2014
Submit Documentation Feedback
Copyright © 2014, Texas Instruments Incorporated