Datasheet
137
TMS570LC4357
www.ti.com
SPNS195C –FEBRUARY 2014–REVISED JUNE 2016
Submit Documentation Feedback
Product Folder Links: TMS570LC4357
System Information and Electrical SpecificationsCopyright © 2014–2016, Texas Instruments Incorporated
Table 6-46. Reset/Abort/Error Sources (continued)
ERROR SOURCE SYSTEM MODE ERROR RESPONSE
ESM HOOKUP
GROUP.CHANNE
L
(2) Oscillator fail/PLL slip can be configured in the system register (SYS.PLLCTL1) to generate a reset.
PSCON compare error User/Privilege ESM 1.38
PSCON self-test error User/Privilege ESM 1.39
Efuse farm
eFuse farm autoload error User/Privilege ESM 3.1
eFuse farm error User/Privilege ESM 1.40
eFuse farm self-test error User/Privilege ESM 1.41
WIndowed Watchdog
WWD Nonmaskable Interrupt Exception N/A ESM 2.24
Errors Reflected in the SYSESR Register
Power-Up Reset N/A Reset N/A
Oscillator fail / PLL slip
(2)
N/A Reset N/A
Watchdog exception N/A Reset N/A
CPUx Reset N/A Reset N/A
Software Reset N/A Reset N/A
External Reset N/A Reset N/A
Register Soft Error User/Privilege ESM 1.90
CPU Interconnect Subsystem
Diagnostic error User/Privilege ESM => Error terminal 3.12
Global error User/Privilege ESM 1.52
Global Parity error User/Privilege ESM 1.53
NMPU for EMAC
MPU Access violation error User/Privilege ESM 1.55
NMPU for PS_SCR_S
MPU Access violation error User/Privilege ESM 1.61
NMPU for DMA Port A
MPU Access violation error User/Privilege ESM 1.69
PCR1
MasterID filtering MPU Access violation error User/Privilege Bus Error N/A
PCR2
MasterID filtering MPU Access violation error User/Privilege Bus Error N/A
PCR3
MasterID filtering MPU Access violation error User/Privilege Bus Error N/A