Datasheet

TMS570LS0432
TMS570LS0332
www.ti.com
SPNS186A OCTOBER 2012REVISED SEPTEMBER 2013
Enhanced power-down mode
Optional feature to automatically power down ADC core when no conversion is in progress
External event pin (ADEVT) programmable as general-purpose I/O
5.2.2 Event Trigger Options
The ADC module supports 3 conversion groups: Event Group, Group1 and Group2. Each of these 3
groups can be configured to be hardware event-triggered. In that case, the application can select from
among 8 event sources to be the trigger for a group's conversions.
5.2.2.1 MIBADC Event Trigger Hookup
Table 5-3. MIBADC Event Trigger Hookup
Event # Source Select Bits For G1, G2 Or Event Trigger
(G1SRC[2:0], G2SRC[2:0] or EVSRC[2:0])
1 000 ADEVT
2 001 N2HET[8]
3 010 N2HET[10]
4 011 RTI compare 0 interrupt
5 100 N2HET[12]
6 101 N2HET[14]
7 110 N2HET[17]
8 111 N2HET[19]
NOTE
For ADEVT, N2HET trigger sources, the connection to the MibADC module trigger input is
made from the output side of the input buffer. This way, a trigger condition can be generated
either by configuring the function as output onto the pad, or by driving the function from an
external trigger source as input. If the mux controller module is used to select different
functionality instead of ADEVT or N2HET[x], care must be taken to disable these signals
from triggering conversions; there is no multiplexing on input connections.
NOTE
For the RTI compare 0 interrupt source, the connection is made directly from the output of
the RTI module. That is, the interrupt condition can be used as a trigger source even if the
actual interrupt is not signaled to the CPU.
Copyright © 2012–2013, Texas Instruments Incorporated Peripheral Information and Electrical Specifications 69
Submit Documentation Feedback
Product Folder Links: TMS570LS0432 TMS570LS0332