Datasheet

6 | C2000™ Piccolo™ TMS320F2806x Microcontroller Series Texas Instruments
C2000™ Piccolo™ TMS230F2806x Microcontroller Series
Feature Guide
Robust System Protection
and Control
Integrated analog comparators are tied
to ADC inputs and provide overcurrent or
overvoltage system protection, asynchro-
nously shutting down (i.e., fault trip) PWM
outputs in as little as 50 ns. Furthermor
e,
with included ramp generation logic,
advanced power stage control—like peak
current mode control—can be imple
-
mented for power supply applications.
See page 521 of the TMS320F2806x Technical Reference Manual to learn more.
Ready-to-Use Analog
Comparators
Analog comparators on C2000 MCUs
come ready-to-use. The analog compar-
ators are tied internally to the ADC input
pins, which means they r
equire no exter-
nal routing or additional pin utilization.
This saves boar
d routing space, frees up
MCU pins for other functions, reduces
latency and makes it easy for designers
to implement system protection.
See pages 84 and 95 of the
TMS320F2806x Data Sheet to
learn more.
Tripping When You Want It
Analog comparators on C2000 MCUs
also include blanking window and filter-
ing features, allowing removal of noise
and unwanted PWM trip triggering.
See page 303 of the
TMS320F2806x Technical
Reference Manual to learn more.