Datasheet

21
CC1310
www.ti.com
SWRS181C SEPTEMBER 2015REVISED OCTOBER 2016
Submit Documentation Feedback
Product Folder Links: CC1310
SpecificationsCopyright © 2015–2016, Texas Instruments Incorporated
ADC Characteristics (continued)
T
c
= 25°C, V
DDS
= 3.0 V, DC-DC disabled. Input voltage scaling enabled, unless otherwise noted.
(1)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Reference voltage
Equivalent fixed internal reference(voltage scaling enabled)
(2)
For best accuracy, the ADC conversion should be initiated
through the TI-RTOS API in order to include the gain/offset
compensation factors stored in FCFG1.
4.3 V
Reference voltage
Fixed internal reference (input voltage scaling disabled).
(2)
For best accuracy, the ADC conversion should be initiated
through the TI-RTOS API in order to include the gain/offset
compensation factors stored in FCFG1. This value is derived
from the scaled value (4.3 V) as follows:
V
ref
= 4.3 V × 1408 / 4095
1.48 V
Reference voltage
VDDS as reference (Also known as RELATIVE) (input voltage
scaling enabled)
VDDS V
Reference voltage
VDDS as reference (Also known as RELATIVE) (input voltage
scaling disabled)
VDDS / 2.82 V
Input Impedance
200 ksamples/s, voltage scaling enabled. Capacitive input,
input impedance depends on sampling frequency and sampling
time
>1 MΩ
(1) Automatically compensated when using supplied driver libraries.
5.12 Temperature Sensor
Measured on the Texas Instruments CC1310EM-7XD-7793 reference design with T
c
= 25°C, V
DDS
= 3.0 V, unless otherwise
noted.
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Resolution 4 °C
Range –40 85 °C
Accuracy ±5 °C
Supply voltage coefficient
(1)
3.2 °C/V
5.13 Battery Monitor
Measured on the Texas Instruments CC1310EM-7XD-7793 reference design with T
c
= 25°C, V
DDS
= 3.0 V, unless otherwise
noted.
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Resolution 50 mV
Range 1.8 3.8 V
Accuracy 13 mV
(1) Additionally, the bias module must be enabled when running in standby mode.
5.14 Continuous Time Comparator
T
c
= 25°C, V
DDS
= 3.0 V, unless otherwise noted.
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Input voltage range 0 V
DDS
V
External reference voltage 0 V
DDS
V
Internal reference voltage DCOUPL as reference 1.27 V
Offset 3 mV
Hysteresis <2 mV
Decision time Step from –10 mV to 10 mV 0.72 µs
Current consumption when enabled
(1)
8.6 µA