Datasheet
14
CC1310
SWRS181C –SEPTEMBER 2015–REVISED OCTOBER 2016
www.ti.com
Submit Documentation Feedback
Product Folder Links: CC1310
Specifications Copyright © 2015–2016, Texas Instruments Incorporated
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating
Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values are with respect to ground, unless otherwise noted.
(3) VDDS2 and VDDS3 must be at the same potential as VDDS.
(4) Including analog-capable DIO
5 Specifications
5.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted)
(1)(2)
MIN MAX UNIT
VDDS
(3)
Supply voltage –0.3 4.1 V
Voltage on any digital pin
(4)
–0.3 VDDS + 0.3, max 4.1 V
Voltage on crystal oscillator pins X32K_Q1, X32K_Q2, X24M_N, and X24M_P –0.3 VDDR + 0.3, max 2.25 V
V
in
Voltage on ADC input
Voltage scaling enabled –0.3 VDDS
VVoltage scaling disabled, internal reference –0.3 1.49
Voltage scaling disabled, VDDS as reference –0.3 VDDS / 2.9
Input RF level 10 dBm
T
stg
Storage temperature –40 150 °C
(1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.
5.2 ESD Ratings
VALUE UNIT
V
ESD
Electrostatic discharge
Human body model (HBM), per ANSI/ESDA/JEDEC JS001
(1)
All pins ±3000
V
Charged device model (CDM), per JESD22-C101
(2)
All pins ±500
(1) For small coin-cell batteries, with high worst-case end-of-life equivalent source resistance, a 22-µF VDDS input capacitor must be used
to ensure compliance with this slew rate.
(2) Applications using RCOSC_LF as sleep timer must also consider the drift in frequency caused by a change in temperature (see 32-kHz
RC Oscillator (RCOSC_LF)).
5.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
Ambient temperature –40 85 °C
Operating supply voltage (VDDS)
For operation in battery-powered and 3.3-V
systems (internal DC-DC can be used to
minimize power consumption)
1.8 3.8 V
Rising supply voltage slew rate 0 100 mV/µs
Falling supply voltage slew rate 0 20 mV/µs
Falling supply voltage slew rate, with low-power flash setting
(1)
3 mV/µs
Positive temperature gradient in standby
(2)
No limitation for negative temperature
gradient, or outside standby mode
5 °C/s