Datasheet

ISO5500
www.ti.com
SLLSE64C SEPTEMBER 2011REVISED JUNE 2013
RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
MIN TYP MAX UNIT
V
CC1
Supply voltage 3 5.5 V
V
OUT(total)
Total output supply voltage (V
CC2
– V
EE-P
) 15 30 V
30V – V
V
OUT+
Positive output supply voltage (V
CC2
– V
E
) 15
(V
E
– V
EE-P
)
V
OUT–
Negative output supply voltage (V
E
– V
EE-P
) 0 15 V
V
C
Collector voltage V
EE-P
+ 8 V
CC2
V
t
ui
Input pulse width 0.1 μs
t
uiR
RESET Input pulse width 0.1 μs
V
IH
High-level input voltage (V
IN+
, V
IN–
, RESET) 2 V
CC
V
V
IL
Low-level input voltage (V
IN+
, V
IN–
, RESET) 0 0.8 V
f
INP
Input frequency 520
(1)
kHz
V
SUP_SR
Supply Slew Rate (V
CC1
or V
CC2
– V
EE-P
)
(2)
75 V/ms
T
J
Junction temperature –40 150 °C
T
A
Ambient temperature -40 25 125 °C
(1) If T
A
= 125°C, V
CC1
= 5.5 V, V
CC2
= 30 V, R
G
= 10 , C
L
= 1 nF
(2) If V
CC1
skew is faster than 75 V/ms (especially for the falling edge) then V
CC2
must be powered up after V
CC1
and powered down before
V
CC1
to avoid output glitches.
Copyright © 2011–2013, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Links :ISO5500