Datasheet

ISO5500
SLLSE64C SEPTEMBER 2011REVISED JUNE 2013
www.ti.com
PARAMETER MEASUREMENT INFORMATION (continued)
Spacer between centered title and PACKAGE CHARACTERISTICS table
PACKAGE CHARACTERISTICS
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Shortest terminal to terminal distance
L
(I01)
Minimum air gap (clearance
(1)
) 8.3 mm
through air
Shortest terminal to terminal distance
L
(I02)
Minimum external tracking (creepage
(1)
) 8.1 mm
across the package surface
Minimum internal gap (internal clearance) Distance through the insulation 0.012 mm
CTI Tracking resistance (comparative tracking index) DIN IEC 60112 / VDE 0303 Part 1 400 V
R
IO
Isolation resistance Input to output, V
IO
= 500 V
(2)
>10
12
C
IO
Barrier capacitance input-to-output V
IO
= 0.4 sin (2πft), f = 1 MHz
(2)
1.25 pF
V
I
= V
CC
/2 + 0.4 sin (2π ft), f = 2 MHz,
C
I
Input capacitance to ground 2 pF
V
CC
= 5V
(1) Creepage and clearance requirements should be applied according to the specific equipment isolation standards of an application. Care
should be taken to maintain the creepage and clearance distance of a board design to ensure that the mounting pads of the isolator on
the printed circuit board do not reduce this distance.space
Creepage and clearance on a printed circuit board become equal according to the measurement techniques shown in the isolation
glossary. Techniques such as inserting grooves and/or ribs on a printed circuit board are used to help increase their specification.
(2) All pins on each side of the barrier tied together creating a two-terminal device
INSULATION CHARACTERISTICS FOR DW-16 PACKAGE
Over recommended operating conditions (unless noted otherwise)
PARAMETER TEST CONDITIONS SPECIFICATION UNIT
Maximum working insulation voltage per DIN
V
IORM
679/480
EN 60747-5-2
After Input/Output safety test subgroup 2/3,
V
PR
= 1.2 x V
IORM
, t = 10 sec, 816/576
Partial discharge < 5 pC
Method a, After environmental tests subgroup 1,
Input to output test voltage per DIN EN
V
PR
V
PR
= 1.6 × V
IORM
, t = 10 sec (qualification) 1088/768
60747-5-2
V
PEAK
/
Partial discharge < 5pC
V
RMS
Method b1, 100% Production test,
V
PR
= 1.875 × V
IORM
, t = 1 sec 1275/900
Partial discharge < 5pC
V
TEST
= V
IOTM
, t = 60 sec (qualification), t = 1 sec
V
IOTM
Transient overvoltage per DIN EN 60747-5-2 6000/4243
(100% production)
V
TEST
= V
ISO
, t = 60 sec (qualification) 6000/4243
V
ISO
Isolation voltage per UL 1577
V
TEST
= 1.2 × V
ISO
, t = 1 sec (100% production) 7200/5092
R
S
Insulation resistance V
IO
= 500 V at T
S
= 150°C > 10
9
Pollution degree 2
REGULATORY INFORMATION
VDE CSA UL
Certified according to DIN EN 60747-5-2 and Approved under CSA Component Recognized under 1577 Component
EN 61010-1 Acceptance Notice 5A Recognition Program
Basic Insulation
Basic and Reinforced Insulation per CSA
Maximum Transient Overvoltage, 6000 V
PK
Single Protection, 4243 V
RMS
(1)
60950-1-07 and IEC 60950-1 (2nd Ed)
Maximum Working Voltage, 680 V
PK
File Number: 40016131 File Number: 220991 File Number: E181974
(1) Production tested 5092 V
RMS
for 1 second in accordance with UL 1577.
18 Submit Documentation Feedback Copyright © 2011–2013, Texas Instruments Incorporated
Product Folder Links :ISO5500