Datasheet

ISO3086T
www.ti.com
SLLSE27C JANUARY 2011 REVISED JULY 2011
IEC INSULATION AND SAFETY RELATED SPECIFICATIONS FOR 16-DW PACKAGE
over recommended operating conditions (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
L(I01) Minimum air gap (Clearance
(1)
) Shortest terminal to terminal distance through air 8.3 mm
L(I02) Minimum external tracking (Creepage
(1)
) Shortest terminal to terminal distance across the 8.1 mm
package surface
CTI Tracking resistance(Comparative Tracking DIN IEC 60112 / VDE 0303 Part 1 400 V
Index)
Minimum Internal Gap (Internal Clearance) Distance through the insulation 0.008 mm
R
IO
Isolation resistance Input to output, V
IO
= 500 V, all pins on each >10
12
Ω
side of the barrier tied together creating a
two-terminal device
C
IO
Barrier capacitance Input to output V
I
= V
CC
/2 + 0.4 sin (2πft), f = 1 MHz, V
CC
= 5 V 2 pF
C
I
Input capacitance to ground V
IO
= 0.4 sin (2πft), f = 1 MHz 2 pF
(1) Creepage and clearance requirements should be applied according to the specific equipment isolation standards of an application. Care
should be taken to maintain the creepage and clearance distance of a board design to ensure that the mounting pads of the isolator on
the printed circuit board do not reduce this distance.
Creepage and clearance on a printed circuit board become equal according to the measurement techniques
shown in the Isolation Glossary. Techniques such as inserting grooves and/or ribs on a printed circuit board are
used to help increase these specifications.
IEC 60664-1 RATINGS TABLE
PARAMETER TEST CONDITIONS SPECIFICATION
Basic isolation group Material group II
Rated mains voltage 150 V
RMS
I-IV
Installation classification Rated mains voltage 300 V
RMS
I-III
Rated mains voltage 400 V
RMS
I-II
IEC 60747-5-2 INSULATION CHARACTERISTICS
(1)
over recommended operating conditions (unless otherwise noted)
PARAMETER TEST CONDITIONS SPECIFICATION UNIT
V
IORM
Maximum working insulation voltage 566 V
PK
V
PR
Input to output test voltage Method b1, V
PR
= V
IORM
× 1.875, 1062 V
PK
100% Production test with t = 1 s,
Partial discharge < 5 pC
Method a, After environmental tests subgroup 1, 906
V
PR
= V
IORM
× 1.6, t = 10 s,
Partial discharge < 5pC
After Input/Output Safety Test Subgroup 2/3, 680
V
PR
= V
IORM
x 1.2, t = 10 s,
Partial discharge < 5 pC
V
IOTM
Maximum transient overvoltage t = 60 s 4242 V
PK
V
IOSM
Maximum surge voltage Tested per IEC 60065 (Qualification Test) 4242 V
PK
R
S
Insulation resistance V
IO
= 500 V at T
S
> 10
9
Ω
Pollution degree 2
(1) Climatic Classification 40/125/21
Copyright © 2011, Texas Instruments Incorporated 11