Datasheet

Input
BInput
90kW
Input
A Input
18kW
16V
V
CC2
16V
18kW
16V
16V
18kW
18kW
V
CC2
Output
A andBOutputs
V
CC2
16V
16V
90kW
ISO1176
www.ti.com
SLLS897D MARCH 2008REVISED MARCH 2010
IEC SAFETY LIMITING VALUES
Safety limiting intends to prevent potential damage to the isolation barrier upon failure of input or output circuitry.
A Failure of the IO can allow low resistance to ground or the supply and, without current limiting, dissipate
sufficient power to overheat the die and damage the isolation barrier potentially leading to secondary system
failures.
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
q
JA
= 212°C/W, V
I
= 5.5 V, T
J
= 170°C,
I
S
Safety input, output, or supply current DW-16 128 mA
T
A
= 25°C
T
S
Maximum case temperature DW-16 150 °C
The safety-limiting constraint is the absolute maximum junction temperature specified in the absolute maximum
ratings table. The power dissipation and junction-to-air thermal impedance of the device installed in the
application hardware determines the junction temperature. The assumed junction-to-air thermal resistance in the
Thermal Characteristics table is that of a device installed in the JESD51-3, Low Effective Thermal Conductivity
Test Board for Leaded Surface Mount Packages and is conservative. The power is the recommended maximum
input voltage times the current. The junction temperature is then the ambient temperature plus the power times
the junction-to-air thermal resistance.
Copyright © 2008–2010, Texas Instruments Incorporated Submit Documentation Feedback 17
Product Folder Link(s) :ISO1176