Datasheet

ISO1050
SLLS983H JUNE 2009REVISED JUNE 2013
www.ti.com
IEC SAFETY LIMITING VALUES
safety limiting intends to prevent potential damage to the isolation barrier upon failure of input or output circuitry. A failure of
the IO can allow low resistance to ground or the supply and, without current limiting dissipate sufficient power to overheat the
die and damage the isolation barrier potentially leading to secondary system failures.
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
θ
JA
= 73.3 °C/W, V
I
= 5.5 V, T
J
= 150°C, T
A
= 25°C 310
DUB-8 mA
θ
JA
= 73.3 °C/W, V
I
= 3.6 V, T
J
= 150°C, T
A
= 25°C 474
I
S
Safety input, output, or supply current
θ
JA
= 76 °C/W, V
I
= 5.5 V, T
J
= 150°C, T
A
= 25°C 299
DW-16 mA
θ
JA
= 76 °C/W, V
I
= 3.6 V, T
J
= 150°C, T
A
= 25°C 457
T
S
Maximum case temperature 150 °C
The safety-limiting constraint is the absolute maximum junction temperature specified in the absolute maximum
ratings table. The power dissipation and junction-to-air thermal impedance of the device installed in the
application hardware determines the junction temperature. The assured junction-to-air thermal resistance in the
Thermal Characteristics table is that of a device installed on a High-K Test Board for Leaded Surface Mount
Packages. The power is the recommended maximum input voltage times the current. The junction temperature is
then the ambient temperature plus the power times the junction-to-air thermal resistance.
REGULATORY INFORMATION
VDE TUV CSA UL
Certified according to DIN EN 60747-5-2 Certified according to EN/UL/CSA Approved under CSA Component Recognized under 1577
60950-1 Acceptance Notice #5A
(1)
Component Recognition
Program
Basic Insulation ISO1050DW: 5000 V
RMS
Reinforced Insulation ISO1050DUB: 2500 V
RMS
Double
Transient Overvoltage, 4000 V
PK
2 Means of Patient Protection at 125 Protection
5000 V
RMS
Reinforced Insulation,
Surge Voltage, 4000 V
PK
V
RMS
per IEC 60601-1 (3rd Ed.) ISO1050DW: 3500 V
RMS
Double
400 V
RMS
maximum working voltage
Maximum Working Voltage, 1200 V
PK
Protection,
5000 V
RMS
Basic Insulation,
(ISO1050DW) and 4243 V
RMS
Single Protection
600 V
RMS
maximum working voltage
560 V
PK
(ISO1050DUB)
ISO1050DUB:
2500 V
RMS
Reinforced Insulation,
400 V
RMS
maximum working voltage
2500 V
RMS
Basic Insulation,
600 V
RMS
maximum working voltage
File Number: 40016131 Certificate Number: U8V 11 09 77311 File Number: 220991 File Number: E181974
008
(1) Production tested 3000 V
RMS
(ISO1050DUB) and 5092 V
RMS
(ISO1050DW) for 1 second in accordance with UL 1577.
THERMAL INFORMATION (DUB-8 PACKAGE)
over recommended operating conditions (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Low-K Thermal Resistance
(1)
120 °C/W
θ
JA
Junction-to-air
High-K Thermal Resistance 73.3 °C/W
Junction-to-board thermal
θ
JB
Low-K Thermal Resistance 10.2 °C/W
resistance
θ
JC
Junction-to-case thermal resistance Low-K Thermal Resistance 14.5 °C/W
V
CC1
= 5.5V, V
CC2
= 5.25V, T
A
=105°C, R
L
= 60,
P
D
Device power dissipation TXD input is a 500kHz 50% duty-cycle square 200 mW
wave
T
j shutdown
Thermal shutdown temperature
(2)
190 °C
(1) Tested in accordance with the Low-K or High-K thermal metric definitions of EIA/JESD51-3 for leaded surface mount packages.
(2) Extended operation in thermal shutdown may affect device reliability.
16 Submit Documentation Feedback Copyright © 2009–2013, Texas Instruments Incorporated
Product Folder Links: ISO1050