Datasheet

ISO1050
www.ti.com
SLLS983H JUNE 2009REVISED JUNE 2013
ISOLATOR CHARACTERISTICS
(1) (2)
over recommended operating conditions (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Shortest terminal to terminal distance through air,
L(I01) Minimum air gap (Clearance) 6.1 mm
per JEDEC package dimensions
DUB-8
Minimum external tracking Shortest terminal to terminal distance across the
L(I02) 6.8 mm
(Creepage) package surface, per JEDEC package dimensions
Shortest terminal to terminal distance through air,
L(I01) Minimum air gap (Clearance) 8.34 mm
per JEDEC package dimensions
DW-16
Minimum external tracking Shortest terminal to terminal distance across the
L(I02) 8.10 mm
(Creepage) package surface, per JEDEC package dimensions
Minimum Internal Gap (Internal
Distance through the insulation 0.014 mm
Clearance)
Input to output, V
IO
= 500 V, all pins on each side of the
barrier tied together creating a two-terminal device,
>10
12
R
IO
Isolation resistance
Tamb < 100°C
Input to output V
IO
= 500 V, 100°C Tamb Tamb max >10
11
C
IO
Barrier capacitance V
I
= 0.4 sin (4E6πt) 1.9 pF
C
I
Input capacitance to ground V
I
= 0.4 sin (4E6πt) 1.3 pF
(1) Creepage and clearance requirements should be applied according to the specific equipment isolation standards of an application. Care
should be taken to maintain the creepage and clearance distance of a board design to ensure that the mounting pads of the isolator on
the printed circuit board do not reduce this distance.
(2) Creepage and clearance on a printed circuit board become equal according to the measurement techniques shown in the Isolation
Glossary. Techniques such as inserting grooves and/or ribs on a printed circuit board are used to help increase these specifications.
INSULATION CHARACTERISTICS
over recommended operating conditions (unless otherwise noted)
PARAMETER TEST CONDITIONS SPECIFICATION UNIT
ISO1050DUB 560
Maximum working insulation
V
IORM
Vpeak
voltage per DIN EN 60747-5-2
ISO1050DW 1200
ISO1050DUB V
P R
= 1.875 x V
IORM
, t = 1 1050
Input to output test voltage per
V
PR
sec (100% production) Vpeak
DIN EN 60747-5-2
ISO1050DW 2250
Partial discharge < 5 pC
t = 60 sec (qualification)
Transient overvoltage per DIN EN
V
IOTM
4000 Vpeak
60747-5-2
t = 1 sec (100% production)
t = 60 sec (qualification) 2500
ISO1050DUB - Double Protection Vrms
t = 1 sec (100% production) 3000
V
ISO
Isolation voltage per UL 1577
t = 60 sec (qualification) 4243
ISO1050DW - Single Protection Vrms
t = 1 sec (100% production) 5092
R
S
Isolation resistance V
IO
= 500 V at T
S
> 10
9
Ω
Pollution Degree 2
IEC 60664-1 RATINGS
PARAMETER TEST CONDITIONS SPECIFICATION
Basic isolation group Material group II
Rated mains voltage 150 Vrms I–IV
Rated mains voltage 300 Vrms I–III
Installation classification Rated mains voltage 400 Vrms I–II
Rated mains voltage 600 Vrms (ISO1050DW only) I-II
Rated mains voltage 848 Vrms (ISO1050DW only) I
Copyright © 2009–2013, Texas Instruments Incorporated Submit Documentation Feedback 15
Product Folder Links: ISO1050