Datasheet

INA330
5
SBOS260
www.ti.com
TYPICAL CHARACTERISTICS
At T
A
= +25°C, V
1
= V
2
= +1V, V
ADJUST
= +2.5V, R
SET
= 10k, R
THERM
= 10k (5%), R
G
= 200k, C
FILTER
= 500pF, and external 1kHz filtering, unless otherwise noted.
CURRENT CONVEYOR OFFSET ERROR
CHANGE OVER TEMPERATURE
PRODUCTION DISTRIBUTION
Current Conveyor Offset Error
Change Over Temperature (nA)
40
36
32
28
24
20
16
12
8
4
0
4
8
12
16
20
24
28
32
36
40
Population
A 40nA current offset error
variation with ambient
temperature results in a
0.009°C variation in set-
point temperature over
40°C to +85°C ambient.
Change in offset error from
+25°C to +85°C, or from
+25°C to 40°C.
CURRENT CONVEYOR OFFSET ERROR
PRODUCTION DISTRIBUTION
Current Conveyor Offset Error (nA)
This error is generally
calibrated out.
209
190
171
152
133
114
95
76
57
38
19
0
19
38
57
76
95
114
133
152
171
190
209
Population
0.01Hz TO 10Hz VOLTAGE NOISE
5s/div
200µV/div
0.0002°C/div
0.001°C
2
3
10
1
V
2
V
EXCITE
1V
Test Configuration
for this page.
V
1
8
7
I
1
I
2
INA330
R
G
200k
10k 10k
V
O
C
FILTER
500pF
+5V
4
2.5V
956